Activation and pre-checks
Unless the dive mode turned off, the dive mode activates automatically when you dive deeper than 1.2 m (4 ft). However, you should switch to dive mode before diving to check altitude and personal settings, battery condition and so on.
Each time your Suunto Zoop Novo enters dive mode, a series of automatic checks are performed. All graphical display elements are turned ON, and the backlight and the beep are activated. After this, your altitude and personal settings are displayed along with the maximum operating depth (MOD), gas content, and PO2 values. Then the battery level is checked.
Between consecutive dives, the automatic checks also show current tissue saturation.
Before leaving on a dive trip, it is highly recommended that you switch to dive mode to make sure everything is functioning properly.
After the automatic checks, Suunto Zoop Novo enters surface mode. At this point, you should perform your manual checks before entering the water.
Ensure that:
-
Suunto Zoop Novo is in the correct mode and provides complete displays.
- Altitude setting is correct.
- Personal setting is correct.
- Deepstops are set correctly.
- Unit system is correct.
- Correct temperature and depth are shown.
- The alarm beeps.
Battery indicators
Temperature or internal oxidation can affect the battery voltage. If you store your Suunto Zoop Novo for a long period or use it in cold temperatures, the low battery warning may appear even though the battery has enough capacity.
In these cases, re-enter dive mode and check the battery power. If the battery is low, the Low Battery warning comes on.
If the low battery icon appears in surface mode, or if the display looks faded, the battery may be too low. Battery replacement is recommended.
NOTE:
For safety reasons, the backlight and buzzer (sound) cannot be activated when the low battery warning is displayed.
Alarms, warnings and notifications
Suunto Zoop Novo has audible and visual alarms designed to let you know when important limits or presets are being reached.
The two audible alarm types indicating indicating high or low priority:
Alarm type |
Sound pattern |
Duration |
High priority |
 |
2.4 s sound + 2.4 s break |
Low priority |
 |
0.8 s sound + 3.2 s break |
In addition, there are two audible guidance notifications:
Instructional beep |
Sound pattern |
Interpretation |
Ascending |
 |
Start ascending |
Descending |
 |
Start descending |
Suunto Zoop Novo displays information during the alarm breaks in order to save battery life.
High priority alarms:
Alarm |
Explanation |
High priority alarm followed by 'Start ascending' beep, repeated for maximum three minutes
PO2 value blinks
|
PO2 value greater than the adjusted value. Current depth is too deep for the gas in use. You should immediately ascend or change to a lower O2% gas. |
High priority alarm followed by 'Start descending' beep, repeated for maximum three minutes Er blinks and an arrow points downwards. |
Decompression ceiling depth exceeded. You should immediately descend to, or below, the ceiling. |
High priority alarm, repeated three times.
SLOW blinks.
|
Maximum ascent rate of 10 m/min (33 ft/min) exceeded. Slow down your ascent rate. |
Low priority alarms:
Alarm type |
Alarm reason |
Low priority alarm followed by 'Start ascending' beep, sounded two times.
ASC TIME blinks and an arrow points upwards.
|
No-decompression dive becomes a decompression stop dive. Depth is below the decompression floor level. You should ascend to, or above, the floor. |
Low priority alarm followed by 'Start descending' beep.
DEEPSTOP blinks and an arrow points downwards.
|
Mandatory deepstop violated. You should descend to complete the deepstop. |
Low priority alarm followed by 'Start descending' beep, repeated for three minutes.
An arrow points downwards.
|
Mandatory safety stop violated. You should descend to complete the safety stop. |
Low priority alarm followed by two short beeps.
DEEPSTOP and timer displayed.
|
Deepstop depth reached. Make the mandatory deepstop for the duration shown by the timer. |
Low priority alarm, repeated twice.
OLF% value blinks if PO2 value is greater than 0.5 bar.
|
OLF value at 80% or 100% (Nitrox dive mode only). Acknowledge the alarm by pressing any button. |
Low priority alarm, repeated twice.
Maximum depth value blinks
|
Defined maximum depth or the maximum depth of the device exceeded. Acknowledge the alarm by pressing any button. |
Low priority alarm, repeated twice; dive time value blinks |
Defined dive time exceeded. Acknowledge the alarm by pressing any button. |
Low priority alarm. Maximum depth value blinks. |
Defined depth reached (Free dive mode only). Acknowledge the alarm by pressing any button. |
Low priority alarm,
Surface time value blinks.
|
Duration of surface time until next dive (Free dive mode only). Acknowledge the alarm by pressing any button. |
Visual alarms
Symbol on display |
Indication |
 |
Attention - extend surface interval |
Er |
Violated decompression ceiling or bottom time is too long |
 |
Do not fly |
Apnea timer
You can use the apnea timer for interval training when freediving. You can adjust the following settings:
-
Vent.: ventilation time; this is the starting duration of the time your breathing time. The time is increased by the increment time for each interval.
-
Incr: increment time; this is added to the ventilation time for each interval. For example, if your ventilation time is 1:00 minute and your increment time is 0:30 seconds, the first interval ventilation is 1:00, the second is 1:30, the third is 2:00, and so on.
-
Repeats: number of intervals
To adjust apnea timer settings:
- While in time mode, keep UP pressed to enter the apnea timer view.
- Keep DOWN pressed to enter apnea timer settings.
- Adjust the ventilation time with UP or DOWN and confirm with SELECT.
- Adjust the increment time with UP or DOWN and confirm with SELECT.
- Adjust the number of intervals with UP or DOWN and confirm with SELECT.
To use the apnea timer:
- Press SELECT to start the first interval. The timer counts down the ventilation time. The countdown continues up to -0:30 seconds beyond the defined ventilation time.
- Press SELECT to start the apnea cycle. You can start this at any time during the ventilation countdown. The apnea time is not defined in the watch. It is as long or short as you choose.
- Press SELECT again to start the next ventilation cycle.
- Repeat until the end of the defined number of intervals.
- Press MODE to exit the apnea timer.
You can reset the apnea timer by keeping SELECT pressed.
The apnea timer supports up to 20 intervals, but this is dependent on the ventilation and increment times. The last ventilation cycle cannot be shorter than 0:05 seconds or longer than 20:00 minutes.
WARNING:
Anyone who engages in any form of breath hold diving is in danger of shallow-water blackout (SWB), the sudden loss of consciousness caused by oxygen starvation.
Ascent rate
The ascent rate is displayed as a vertical bar along the right side of the display.
When the maximum allowed ascent rate is exceeded, the lower segment of the bar starts to blink and the top segment stays solid.
Continuous ascent rate violations result in mandatory safety stops. See Safety stops and deepstops .
WARNING:
DO NOT EXCEED THE MAXIMUM ASCENT RATE! Rapid ascents increase the risk of injury. You should always make the mandatory and recommended safety stops if you have exceeded the maximum recommended ascent rate. If the mandatory safety stop is not completed, the decompression algorithm penalizes your next dive(s).
Backlight
To active the backlight while diving, press MODE.
Otherwise, keep MODE pressed until the backlight activates to use the backlight.
You can define how long the backlight stays on when you activate it or turn the backlight off altogether.
To set backlight duration:
- While in time mode, keep DOWN pressed.
- Press DOWN to scroll to Backlight and press SELECT.
- Set duration or turn off with DOWN or UP.
- Press MODE to save and exit to settings.
NOTE:
When the backlight is off, it does not illuminate when an alarm sounds.
Bookmarks
At any time during a dive, you can add a bookmark to the dive log by pressing SELECT.
You can view bookmarks when scrolling the dive profile in the logbook.
Each bookmark records present depth, time, and water temperature.
Calendar clock
The calendar clock is the default mode of Suunto Zoop Novo .
Time
In the time settings, you can set the hours, minutes, seconds, and format (12 or 24-hour).
To set time:
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Time and press SELECT.
- Set hours with DOWN or UP and confirm with SELECT.
- Repeat for minutes and seconds. Set the format with DOWN or UP and confirm with SELECT.
- Press MODE to exit.
Date
The date and weekday are shown in the bottom row of time mode. Press DOWN to toggle between views.
To set the date:
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Date and press SELECT.
- Set year with DOWN or UP and accept with SELECT.
- Repeat for month and day.
- Press MODE to exit.
Units
In the units setting, choose whether the units are displayed in the metric or Imperial system.
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Units and press SELECT.
- Press DOWN to toggle between Metric and Imperial and confirm with SELECT.
- Press MODE to exit.
Dual time
Dual time allows you to keep track of the time in a second time zone. Dual time is shown in the bottom left of the time mode display by pressing DOWN.
To set dual time:
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Dual Time and press SELECT.
- Set hours with DOWN or UP and confirm with SELECT.
- Repeat for minutes.
- Press MODE to exit.
Alarm clock
Suunto Zoop Novo has a daily alarm which can be set to activate once, on weekdays or every day.
When the daily alarm activates, the screen blinks and the alarm sounds for 60 seconds. Press any button to stop the alarm.
To set the daily alarm:
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Alarm and press Select.
- Select alarm activation with DOWN or UP and confirm with Select. The options are Off, Once, Weekdays, or Every Day.
- Set hours with DOWN or UP and confirm with SELECT.
- Repeat for minutes.
- Press MODE to exit.
Decompression dives
If you exceed the no-decompression limit on a dive, when NO DEC TIME reaches zero, your dive changes into a decompression dive. Therefore, you must perform one or more decompression stops on your way to the surface.
When the decompression dive starts, the NO DEC TIME on your display is replaced by ASC TIME, and a CEILING indicator appears. An upward pointing arrow also prompts you to start your ascent.
Suunto Zoop Novo provides the decompression information required for ascent with two key values:
-
CEILING: depth that you should not go above
-
ASC TIME: optimum ascent time in minutes to surface with defined gases
If you exceed the no-decompression limits on a dive, the dive computer provides the decompression information required for ascent along with subsequent details that are updated as you ascend.
In other words, rather than requiring you to make stops at fixed depths, the dive computer lets you decompress within a range of depths. This is known as continuous decompression.
Ceiling, ceiling zone, floor and decompression range
Before you do a decompression dive, you need to understand the meaning of ceiling, ceiling zone, floor, and decompression range. You need to understand these concepts to be able to correctly interpret the guidance provided by the dive computer.
- The ceiling is the shallowest depth to which you should ascend when doing decompression.
- The ceiling zone is the optimum decompression depth range. It is the range between the ceiling depth and 1.2 m (4 ft) below that ceiling.
- The floor is the deepest depth at which the decompression stop time does not increase. Decompression starts when you pass this depth during your ascent.
- The decompression range is the depth range between the ceiling and floor. Within this range, decompression takes place. However, it is important to remember that the decompression slower at or close to the floor compared to the ceiling zone.
The depth of the ceiling and floor depends on your dive profile. The ceiling depth is fairly shallow when you first enter the decompression dive. But if you remain at depth, the ceiling depth moves downward, and the ascent time increases. The opposite is also true: the floor and ceiling depths may change upwards while you are decompressing.
When conditions are rough, it may be difficult to maintain a constant depth near the surface. In such cases, it is more manageable to maintain a depth somewhat below the ceiling, to ensure that the waves do not lift you above the ceiling. Suunto recommends that you decompress deeper than 4 m (13 ft), even if the indicated ceiling is shallower.
Ascent time
The ascent time shown on your dive computer is the minimum amount of time needed to reach the surface on a decompression dive. This includes:
- Time required to do deepstops
- Ascent time from depth at an ascent rate of 10 m (32.8 ft) per minute
- Time needed for decompression
- Time needed for extra safety stops if ascending too fast during the dive
WARNING:
Your actual ascent time may be longer than displayed by Suunto Zoop Novo. It may be longer if your ascending speed is slower than 10 m (32.8 ft) per minute or you are doing a decompression stop deeper than the recommended ceiling. Take this into account, since it might increase the amount of required breathing gas to reach the surface.
Decompression guidance
On a decompression dive, there can be three kinds of stops:
- Safety stop
- Deepstop
- Decompression stop
Though not recommended, you may break (ignore) deepstops and safety stops. Suunto Zoop Novo penalizes such actions with additional stops or other measures, either during the dive or on following dives. For more information, see Safety stops and deepstops.
Suunto Zoop Novo shows the ceiling value always from the deepest of these stops. Deepstop and safety stop ceilings are always at constant depth when you are at the stop. Stop time is counted down in minutes and seconds.
With decompression stops, the ceiling is always decreasing while you are near the ceiling depth, providing continuous decompression with optimum ascent time.
NOTE:
It is always recommended to keep close to the decompression ceiling when ascending.
Below the floor
The blinking ASC TIME text and an upward arrow indicate that you are below the floor. A low priority alarm will also sound. You should start your ascent immediately. The ceiling depth is shown on the left side of the center field, and the minimum total ascent time on the right side.
Below is an example of a decompression dive with a ceiling of 3 m and total ascent time of 9 minutes.
Above the floor
When you ascend above the floor, the ASC TIME text stops blinking and the upward arrow disappears, as shown below.
This indicates you are in the decompression range. Decompression begins, but slowly. Therefore, you should continue your ascent.
At the ceiling
When you reach the ceiling zone, the display will show you two arrows pointing at each other as shown below.
During the decompression stop, your total ascent time continues to count down towards zero. If the ceiling moves upwards, you can ascend to the new ceiling.
You may surface only after ASC TIME and CEILING have disappeared. This means that the decompression stop and any mandatory safety stop have been completed.
You are advised, however, to stay below the ceiling until the STOP text has also disappeared. This indicates that the three (3) minute recommended safety stop has also been completed.
Above the ceiling
If you ascend above the ceiling during a decompression stop, a downward arrow appears in from of the ceiling depth, and a continuous beeping starts.
In addition, an error warning Er reminds you that you have only three (3) minutes to correct the situation. You must immediately descend to, or below, the ceiling. If you continue to violate the decompression, the dive computer goes into a permanent error mode (Error state (algorithm lock)).
Depth alarm
By default the depth alarm sounds at 30 m (100 ft). You can adjust the depth according to your personal preference or switch it off.
To adjust the depth alarm:
- While in a dive mode, keep DOWN pressed to enter settings.
- Press UP to scroll to Depth Alarm and press SELECT.
- Press UP to toggle the alarm on/off and confirm with SELECT.
- Adjust depth with DOWN or UP and accept with SELECT.
- Press MODE to exit.
When the depth alarm activates, the backlight blinks and the low priority audible alarm pattern sounds. Acknowledge the alarm by pressing any button.
Display contrast
You can adjust the contrast of the display according to your preference or, for example, to suite changing dive conditions.
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Contrast and press Select.
- Use DOWN or UP to change the contrast from 0 (lowest) to 10 (highest).
- Press MODE to exit.
Dive history
Suunto Zoop Novo has a detailed logbook and dive history available in memory mode.
The logbook contains a sophisticated dive profile for each recorded dive. The time between each data point saved in the log is based on the configurable sample rate (see Sample rate).
The dive history is a summary of all recorded dives.
To access dive history:
- Press MODE until you see MEM.
- Switch between History and Logbookwith DOWN or UP.
- When you are viewing the history or logbook, you can press MODE to go back and select the other one. Press MODE a second time to exit.
History
When you have entered the dive history view, you can switch between Scuba History and Free Dive History with DOWN and UP.
Scuba dive history shows you a summary of the following:
- Dive hours
- Total number of dives
- Maximum depth
The scuba dive history records a maximum of 999 dives and 999 diving hours. When these limits are reached, the counters reset to zero.
Free dive history shows the following:
- the deepest and the longest dives of all free dives
- the cumulative dive time in hours and minutes
- the total number of dives
The free dive history records a maximum of 999 dives and 99:59 diving hours. When these limits are reached, the counters are reset to zero.
Logbook
Each log has three pages:
- Main page

- maximum depth
- date of dive
- type of dive (indicated by first letter of dive mode, e.g. A for Air mode)
- dive start time
- dive number – from oldest to newest
- gas percentage(s) of the first used gas mix
- total dive time (in minutes in all modes)
- Surface time and warnings page

- maximum depth
- surface time after previous dive
- average depth
- warnings
- OLF% (if applicable)
- Dive profile graph

- water temperature
- depth/time profile of the dive
Press UP to scroll through the dive profile graph or keep UP pressed to auto-scroll.
The dive profile graph shows point by point dive information such as depth, compass heading, decompression info, ceiling and ascent time.
The End of Logs text is displayed between the oldest and most recent dive.
The logbook capacity depends on the sample rate.
If the memory is full, when new dives are added, the oldest dives are deleted.
The contents of the memory remain when the battery is changed (providing that the battery has been replaced according to the instructions).
NOTE:
Several repetitive dives are considered to belong to the same repetitive dive series if the no-fly time has not ended.
Dive modes
Suunto Zoop Novo has the following dive modes:
-
Air: for diving with regular air
-
Nitrox: for diving using oxygen-enriched gas mixtures
-
Gauge: for using the dive computer as a bottom timer
-
Free: for freediving
-
Off: turns dive mode off completely; the dive computer does not automatically switch the dive mode when submerged and dive planning mode is hidden
By default, Air mode is activated when you enter dive mode. You can change which mode is activated or turn dive mode off under the general settings.
To change dive modes:
- While in time mode, keep DOWN pressed.
- Press SELECT to enter Dive Mode.
- Change to the desired mode with UP or DOWN and confirm with SELECT.
- Press MODE to exit.
Each dive mode has its own settings which you need to adjust while in the given mode.
To modify dive mode settings:
- While in a given dive mode, keep DOWN pressed.
- Press DOWN or UP to scroll through the settings.
- Press SELECT to enter a setting.
- Adjust the setting with DOWN or Up and confirm with SELECT.
- Press MODE to exit.
NOTE:
Some settings cannot be changed until five (5) minutes have elapsed after the dive.
Air mode
Air mode is for diving with regular air and has the following settings:
- Personal/altitude adjustment (see Personal and altitude adjustments)
- Depth alarm (see Depth alarm)
- Dive time alarm (see Dive time alarm)
- Sample rate (see Sample rate)
- Deepstop (see Safety stops and deepstops)
Nitrox mode
Nitrox mode is for diving with oxygen-enriched gas mixtures.
Diving with nitrox allows you to increase bottom times or reduce the risk of decompression illness. However, when the gas mix is altered or depth increased, the oxygen partial pressure is generally increased. Suunto Zoop Novo provides you with information to adjust your dive and stay within safe limits.
Nitrox mode has the following settings
- Nitrox (gas mixture)
- Personal/altitude adjustment (see Personal and altitude adjustments)
- Depth alarm (see Depth alarm)
- Dive time alarm (see Dive time alarm)
- Sample rate (see Sample rate)
- Deepstop (see Safety stops and deepstops)
In Nitrox mode, both the percentage of oxygen in your tank and the oxygen partial pressure limit must be entered into Suunto Zoop Novo.
This ensures correct nitrogen and oxygen calculations and the correct maximum operating depth (MOD), which is based on your entered values.
The default oxygen percentage (O2%) setting is 21% (air) and oxygen partial pressure (PO2) setting is 1.4 bar (20 psi).
To modify gas mix settings:
- While in Nitrox mode, keep DOWN pressed.
- Press SELECT to enter the Nitrox setting.
- Adjust the O2 value with DOWN or UP to match the oxygen percentage of your tank and confirm with SELECT.
- Adjust the PO2 (oxygen partial pressure) value with DOWN or UP and accept with SELECT.
- Adjust other settings as needed.
- Press MODE to exit.
NOTE:
If the oxygen content of a mix is set to 22% or above, the setting value remains until changed. It does not automatically revert back to 21%.
Gauge mode
With Gauge mode, you can use Suunto Zoop Novo as a bottom timer.
The timer in the center of the display shows dive time in minutes and seconds and activates at the start of the dive. The total running dive time, in minutes, is in the lower right corner.
The timer in the center of the display can be used as a stopwatch by pressing SELECT during the dive.
Pressing SELECT resets the main timer and adds a bookmark to the dive log. The previously-timed interval is displayed below the main timer.
Gauge mode has the following settings
- Depth alarm (see Depth alarm)
- Dive time alarm (see Dive time alarm)
- Sample rate (see Sample rate)
Gauge mode is a bottom timer only and thus includes no decompression information or calculations.
Free mode
With Free mode, Suunto Zoop Novo can be used as a freediving instrument. The dive time is indicated in minutes and seconds in the center of the display.
The free dive starts at 1.2 m (4 ft) and ends when your depth is less than 0.9 m (3 ft).
Free mode has the following settings:
- Depth notifications (see Depth notifications)
- Depth alarm (see Depth alarm)
- Dive time alarm (see Dive time alarm)
- Surface timer (see Surface and no-fly time )
- Sample rate (see Sample rate)
Depth notifications
You can define up to five independent depth notifications for freediving, for example, to alert you to start free falling or mouth filling. Each notification has a defined depth and can be turned on or off.
When you reach the notification depth, the backlight blinks and the low priority audible alarm sounds.
To define depth notifications:
- While in Free mode, keep DOWN pressed.
- Press SELECT to enter the Depth Notify settings.
- Scroll through the notifications with DOWN or UP and enter a notification with SELECT.
- Press DOWN or UP to toggle the notification On/Off and confirm with SELECT.
- Adjust the depth with DOWN or UP and confirm with SELECT.
- Scroll to the next notification to modify or press MODE to exit.
Surface countdown timer
While freediving, you can use the surface countdown timer to help you prepare yourself for you next dive. Suunto Zoop Novo starts the countdown as soon as you reach 1.2 m (4 ft).
To set the surface countdown timer:
- While in Free mode, keep DOWN pressed.
- Press UP to scroll to Surf. Time Notify.
- Press DOWN or UP to toggle the timer on and confirm with SELECT.
- Adjust the countdown duration with DOWN or UP and conform with SELECT.
- Press MODE to exit.
Dive numbering
If the Suunto Zoop Novo has not counted the no-fly time down to zero, then repetitive dives belong to the same dive series.
Within each series, the dives are given numbers. The first dive of the series is DIVE 1, the second DIVE 2, and so on.
If you start a new dive with less than five (5) minutes at the surface, Suunto Zoop Novo treats the new dive as part of the previous dive. The dive time continues where it left off.
After five (5) minutes or more at the surface, any new dives are part of a repetitive dive series. The dive counter displayed in the planning mode adds one to each new dive in the repetitive series.
The planning mode allows you to review the no-decompression limits on the next dive in a series.
Dive planning mode
The dive planning mode PLAN NoDeco can be used to plan a dive that does not require decompression. You enter the depth of your upcoming dive, and Suunto Zoop Novo calculates the maximum time you can stay at that depth without requiring decompression stops.
The dive plan takes into account:
- any calculated residual nitrogen
- dive history from the past four days
To plan dives:
- Press MODE until you see PLAN NoDec.
- The display briefly shows your remaining desaturation time before continuing to the planning display.
- Press DOWN or UP to scroll your upcoming dive depths. The depth moves in 3 m (10 ft) increments from 9 m – 45 m (30 ft – 150 ft). The no-decompression time limit for the selected depth is shown in the center of the display. If you have dived at least once with Suunto Zoop Novo, the SURFTIME + field appears. You can adjust the surface time with UP.
- Between consecutive dives, you can press SELECT to adjust surface time.
- Press MODE to exit.
NOTE:
The dive planning mode is disabled if the dive computer is in an error state (see Error state (algorithm lock)) or if the dive mode is off or in Gauge mode.
Dive time alarm
The dive time alarm can be activated and used for several purposes to add to your diving safety. It is simply a countdown timer in minutes.
To set the dive time alarm:
- While in a relevant dive mode, keep DOWN pressed.
- Press DOWN or UP to scroll to Alarm Time.
- Press UP to toggle the alarm on and press SELECT to confirm.
- Adjust the duration with UP or DOWN and accept with SELECT.
- Press MODE to exit.
Error state (algorithm lock)
Suunto Zoop Novo has warning indicators that alert you to react to certain situations that would significantly increase the risk of DCI. If you do not respond to these warnings, Suunto Zoop Novo enters an error state and shows Er on the display. This indicates that the risk of DCI has greatly increased.

If you omit decompression stops for longer than three (3) minutes, the RGBM algorithm is locked for 48 hours. When the algorithm is locked, no algorithm information is available and Er is shown instead. Locking the algorithm is a safety feature, highlighting that the algorithm information is no longer valid.
In such a condition, you should descend back below the ceiling level to continue the decompression. If you fail to do so within three (3) minutes, Suunto Zoop Novo locks the algorithm calculation and displays Er instead, as shown below. Note that the ceiling value is no longer present.
In this state, you significantly increase your risk of decompression sickness (DCS). Decompression information is not available for the next 48 hours after surfacing.
It is possible to dive with the device when the algorithm is locked, but instead of the decompression information, Er is shown.
If you dive again in this error state, the algorithm lock time resets to 48 hours when you surface.
Personal and altitude adjustments
There are several factors that can affect your susceptibility to DCS. Such factors vary between divers and from one day to another.
The personal factors which tend to increase the possibility of DCS include:
- exposure to cold water - less than 20°C (68 °F)
- below average physical fitness level
- fatigue
- dehydration
- stress
- obesity
- patent foramen ovale (PFO)
- exercise before or after dive
The three-step personal setting can be used to adjust the algorithm to fit your DCS susceptibility.
Personal adjustment |
Explanation |
0 |
Ideal conditions (default value). |
1 |
Conservative. Some risk factors or conditions exist. |
2 |
More conservative. Several risk factors or conditions exist. |
In addition to the personal setting, Suunto Zoop Novo can be adjusted for diving at different altitudes. This adjusts the decompression calculation according to the selected altitude adjustment.
Altitude adjustment |
Explanation |
0 |
0 – 300 m (0 – 980 ft) (default) |
1 |
300 – 1500 m (980 – 4900 ft) |
2 |
1500 – 3000 m (4900 – 9800 ft) |
To change the personal and altitude adjustment settings:
- While in a dive mode, keep DOWN pressed.
- Press SELECT to enter Personal Altitude settings.
- Press UP to change the Personal adjustment and confirm with SELECT.
- Press UP to change the Altitude adjustment and confirm with SELECT.
- Press MODE to exit.
WARNING:
Traveling to a higher altitude can temporarily cause changes to the equilibrium of dissolved nitrogen in the body. It is recommended that you acclimatize to the new altitude by waiting at least three (3) hours before diving.
Power save mode
Suunto Zoop Novo display turns off after 30 minutes of inactivity to save battery time. To turn the display back on, press any button.
Safety stops and deepstops
Safety stops are widely considered good diving practice and are a critical part of most dive tables. The reasons for performing a safety stop include: reducing sub-clinical DCI, microbubble reduction, ascent control, and orientation before surfacing.
Suunto Zoop Novo displays two different types of safety stops: recommended and mandatory.
With every dive over 10 meters (30 feet), there is a three-minute countdown for the recommended safety stop. This stop is taken in the 3-6 m (10-20 ft) range. Suunto Zoop Novo shows a STOP icon and a three-minute countdown.
NOTE:
When deepstops are enabled, the length of mandatory safety stops is indicated in seconds.
When the ascent rate exceeds 10 m (33 ft) per minute for more than five consecutive seconds, the microbubble build-up may be more than is allowed for in the decompression model.
In this situation, Suunto Zoop Novo adds a mandatory safety stop to the dive. The time of this stop depends on the speed violation of the ascent rate.
The STOP icon is shown in the display. When you reach the depth zone between 6 m and 3 m (18 ft and 9 ft) the following is displayed:
-
CEILING and STOP
- Ceiling depth
- Safety stop time
Wait at the ceiling until the mandatory safety stop warning disappears.
WARNING:
NEVER ASCEND ABOVE THE CEILING! You must not ascend above the ceiling during your decompression. In order to avoid doing so by accident, you should stay somewhat below the ceiling.
Deepstops activate when you dive deeper than 20 m (65.6 ft).
If the dive timer is on the screen when deepstop activates, the timer is replaced with deepstop.
After deepstop is over, the user can change between deepstop and the timer by long pressing the MODE button.
Deepstops are presented the same way as safety stops. Suunto Zoop Novo notifies you that you are in the deepstop area by displaying:
-
CEILING in the top
-
DEEPSTOP in the center row
- Stop depth
- Countdown timer
Deepstop is on by default in Air and Nitrox modes. To turn deepstop off:
- While in a dive mode, keep DOWN pressed.
- Press DOWN to scroll to Deepstop and enter with Select.
- Press UP to toggle on/off.
- Press MODE to exit.
Sample rate
The sample rate controls how often information from the dive is saved to the active log. The default sample rate is 20 seconds in air and nitrox modes, and 2 seconds in free dive mode.
To change the sample rate:
- While in a dive mode, keep DOWN pressed.
- Press UP to scroll to Sample Rate and press SELECT.
- Press DOWN or UP to change the rate and confirm with SELECT.
- Press MODE to exit.
The sample rate options in air and nitrox modes are: 10, 20, 30 and 60 seconds.
The sample rate options in free dive mode are: 1, 2 and 5 seconds.
Software version
You can check the software version and battery status of Suunto Zoop Novo under the general settings.
- While in time mode, keep DOWN pressed.
- Press UP to scroll to Version and press SELECT.
- The software version is displayed along with the battery voltage.
Stopwatch
The stopwatch can be used to measure elapsed and split times.
To activate the stopwatch:
- While in time mode, scroll through the bottom row view by pressing UP or DOWN until the stopwatch is displayed.
- Press SELECT to start/stop the stopwatch.
- Press DOWN to take split times.
- Keep SELECT pressed to reset the stopwatch.
After stopping the stopwatch, you can scroll through the split times with DOWN.
You can also use the stopwatch while diving for various timing purposes. To activate the stopwatch in dive mode, keep MODE pressed.
Start and stop the stopwatch by pressing SELECT.
NOTE:
If a deepstop activates while you are using the stopwatch, the timer field is not visible.
Surface and no-fly time
Once back at the surface, Suunto Zoop Novo continues to provide post-dive safety information and alarms. If, after your dive, you need to wait until flying, the no-fly symbol displays in all modes.

To access further information about your surface and no-fly times, enter dive mode.
Suunto Zoop Novo shows the time since you surfaced in the Surf t. field. The airplane symbol indicates that you should not fly. The countdown until you will be safe to fly is shown in the No Fly field.
No-fly time is always at least 12 hours and equals desaturation time when it is more than 12 hours. For desaturation times shorter than 70 minutes, the no-fly time is not displayed.
If decompression is omitted during a dive so that Suunto Zoop Novo enters error state (see Error state (algorithm lock)), the no-fly time is always 48 hours.
If a dive is done in Gauge mode (bottom timer), the no-fly time is 48 hours.
WARNING:
YOU ARE ADVISED TO AVOID FLYING ANY TIME THE COMPUTER COUNTS DOWN THE NO-FLY TIME. ALWAYS ACTIVATE THE COMPUTER TO CHECK THE REMAINING NO-FLY TIME PRIOR TO FLYING! Flying or traveling to a higher altitude within the no-fly time can greatly increase the risk of DCS. Review the recommendations given by Divers Alert Network (DAN). There can never be a flying-after-diving rule that is guaranteed to completely prevent decompression sickness!
The Divers Alert Network (DAN) recommends the following on no-fly times:
- A minimum surface interval of 12 hours would be required in order to be reasonably assured a diver will remain symptom free upon ascent to altitude in a commercial jetliner (altitude up to 2,400 m (8,000 ft)).
- Divers who plan to make daily, multiple dives for several days, or make dives that require decompression stops, should take special precautions and wait for an extended interval beyond 12 hours before a flight. Further, the Undersea and Hyperbaric Medical Society (UHMS) suggests divers using standard air cylinders and exhibiting no symptoms of decompression sickness wait 24 hours after their last dive to fly in an aircraft with cabin pressure up to 2,400 m (8,000 ft). The only two exceptions to this recommendation are:
- If a diver has less than two (2) hours total accumulated dive time in the last 48 hours, a 12 hour surface interval before flying is recommended.
- Following any dive that required a decompression stop, flying should be delayed for at least 24 hours, and if possible, for 48 hours.
Suunto recommends that flying is avoided until all the DAN and UHMS guidelines, as well as the dive computer’s no-fly conditions, are satisfied.
Suunto RGBM
Suunto's decompression model development originates from the 1980s when Suunto implemented Bühlmann's model based on M-values in Suunto SME. Since then research and development has been ongoing with the help of both external and internal experts.
In the late 1990s, Suunto implemented Dr. Bruce Wienke's RGBM (Reduced Gradient Bubble Model) bubble model to work with the earlier M-value based model. The first commercial products with the feature were the iconic Suunto Vyper and Suunto Stinger. With these products the improvement of diver safety was significant as they addressed a number of diving circumstances outside the range of dissolved-gas-only models by:
- Monitoring continuous multiday diving
- Computing closely spaced repetitive diving
- Reacting to a dive deeper than the previous dive
- Adapting to rapid ascents which produce high microbubble (silent-bubble) build-up
- Incorporating consistency with real physical laws for gas kinetics
The Suunto RGBM predicts both dissolved and free gas in the blood and tissues of divers. It is a significant advancement on the classic Haldane models, which do not predict free gas. The Suunto RGBM provides additional safety through its ability to adapt to a variety of situations and dive profiles.
Diver Safety
Because any decompression model is purely theoretical and does not monitor the actual body of a diver, no decompression model can guarantee the absence of DCS. Experimentally it has been shown that the body adapts to decompression to some degree when diving is constant and frequent. Personal adjustment settings are available for divers who dive constantly and are ready to accept greater personal risk.
CAUTION:
Always use the same personal and altitude adjustment settings for the actual dive and for the planning. Increasing the personal adjustment setting from the planned setting as well as increasing the altitude adjustment setting can lead to longer decompression times deeper and thus to larger required gas volume. You can run out of breathing gas underwater if the personal adjustment setting has been changed after dive planning.
Altitude diving
The atmospheric pressure is lower at high altitudes than at sea level. After traveling to a higher altitude, you will have additional nitrogen in your body, compared to the equilibrium situation at the original altitude. This 'additional' nitrogen is released gradually over time and equilibrium is restored. It is recommended that you acclimatize to a new altitude by waiting at least three hours before making a dive.
Before high-altitude diving, you need to adjust the altitude settings of your dive computer so that the calculations take into account the high altitude. The maximum partial pressures of nitrogen allowed by the mathematical model of the dive computer are reduced according to the lower ambient pressure.
As a result, the allowed no decompression stop limits are considerably reduced.
WARNING:
SET THE CORRECT ALTITUDE SETTING! When diving at altitudes greater than 300 m (1000 ft), the altitude setting must be correctly selected in order for the computer to calculate the decompression status. The dive computer is not intended for use at altitudes greater than 3000 m (10000 ft). Failure to select the correct altitude setting or diving above the maximum altitude limit will result in erroneous dive and planning data.
Oxygen exposure
The oxygen exposure calculations are based on currently accepted exposure time limit tables and principles.
The dive computer calculates separately the Central Nervous System oxygen toxicity (CNS) and the Pulmonary Oxygen toxicity, the latter measured by the addition of Oxygen Toxicity Units (OTU).
Both fractions are scaled so that the diver’s maximum tolerated exposure for each is 100%.
Suunto Zoop Novo does not display CNS% or OTU% but instead displays the larger of the two in the OLF% field. OLF% value is the Oxygen limit fraction or Oxygen Toxicity Exposure.
For example, if the diver’s maximum tolerated exposure for CNS% is 85% and the maximum tolerated exposure for OTU% is 80% the OLF% displays the largest scaled value, here 85%.
Oxygen related information displayed by the dive computer is also designed to ensure that all warnings and displays occur at the appropriate phases of a dive.
WARNING:
WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY TAKE ACTION TO REDUCE OXYGEN EXPOSURE. Failure to take action to reduce oxygen exposure after a CNS/OTU warning is given can rapidly increase the risk of oxygen toxicity, injury, or death.
Tones
Device tones can be turned on or off. When tones are off, there are no audible alarms.
To set tones:
- While in time mode, keep DOWN pressed.
- Press DOWN or UP to scroll to Tones and press SELECT.
- Press DOWN or UP to toggle on/off and confirm with SELECT.
- Press MODE to exit.
Water contact
The water contact is located on the side of the case. When submerged, the water contact poles are connected by the conductivity of the water. Suunto Zoop Novo switches to dive state when water is detected and the depth gauge senses water pressure at 1.2 m (4 ft).
The AC is shown until the water contact deactivates. It is important to keep the water contact area clean. Contamination or dirt can prevent automatic activation/deactivation.
NOTE:
Moisture build-up around the water contact may cause the dive mode to activate. This can happen, for example, when washing your hands or sweating. To save battery power, deactivate the water contact by cleaning it and/or drying it with a soft towel.