What Is Nitrox Diving?
Nitrox diving, also called enriched air diving, means scuba diving with a breathing gas that contains more oxygen than regular air. It's a common form of recreational diving.
The gas is made up mainly of oxygen and nitrogen and is known as Enriched Air Nitrox (EANx). It comes in different oxygen percentages, with EAN32 and EAN36 among the most common. The number shows the oxygen percentage: EAN32 contains 32% oxygen, and EAN36 contains 36% oxygen.
These labels also form the starting point for your dive plan. Every Nitrox dive begins with knowing the actual gas composition and planning around it.
Nitrox vs. Normal Air: What's the Difference?
The key difference between Nitrox and regular air is the balance of oxygen and nitrogen. Nitrox has a higher percentage of oxygen and a lower percentage of nitrogen, which changes both your nitrogen and oxygen exposure during a dive.
| Gas Type |
Oxygen Percentage |
Nitrogen and Other Gases |
| Regular air |
Approximately 21% |
Approximately 79% |
| EAN32 |
32% |
Approximately 68% |
| EAN36 |
36% |
Approximately 64% |
Note: Percentages shown are approximate and for general reference. Air and other gas mixtures may also contain small amounts of other gases.

How Does Nitrox Affect No-Decompression Limits (NDL)?
With a lower nitrogen percentage, Nitrox generally gives you a longer calculated no-decompression limit (NDL) than regular air, assuming other conditions are comparable.
Because Nitrox contains less nitrogen, the nitrogen partial pressure in your breathing gas is lower at any given depth. That reduces the pressure driving nitrogen into your tissues, so you absorb less of it. NDL is the estimated time you can stay at your current depth, under current conditions, without needing mandatory decompression stops. Your dive computer estimates the inert gas load in your tissues using a decompression model, based on your gas settings, depth, dive time and dive history, and calculates NDL from that estimate.
Your actual NDL also depends on depth, time underwater and previous dives. Different dive computers can give different NDL estimates because they use different decompression models and conservatism settings.
To better understand the NDL reading on your dive computer, explore how it’s calculated and what the remaining time means.
Along with NDL, Nitrox divers also need to monitor oxygen partial pressure (ppO₂) and maximum operating depth (MOD). The next section explains how both relate to depth.
How Does Nitrox Affect Maximum Operating Depth (MOD)?
How Oxygen Content Determines MOD
The oxygen percentage in a Nitrox mixture and the depth of the dive together determine the oxygen partial pressure (ppO₂) in the breathing gas. According to Dalton's Law of Partial Pressures, oxygen partial pressure is calculated by multiplying the oxygen fraction by the absolute ambient pressure at the current depth:
ppO2 = FO₂ × Pabs
Here, FO₂ is the oxygen fraction expressed as a decimal, and Pabs is the absolute ambient pressure, including atmospheric pressure at the surface. This means that even when using the same Nitrox mixture, ppO₂ increases as you descend because ambient pressure increases. At the same depth, a mixture with a higher oxygen percentage produces a higher ppO₂.
For more background on how pressure changes affect scuba divers, see our introduction to diving physics and decompression models.
Maximum Operating Depth (MOD) is the depth limit calculated from the oxygen percentage in a gas mixture and the selected ppO₂ limit. It represents the depth at which the oxygen partial pressure in the breathing gas reaches the limit chosen for the dive.
At the same ppO₂ limit, a higher oxygen percentage requires a lower ambient pressure to reach that limit, resulting in a shallower MOD. Conversely, even when using the same gas mixture, different ppO₂ limits will produce different MOD calculations. Therefore, MOD is not a fixed depth that applies to all Nitrox mixtures. It is determined by both the gas composition and the selected oxygen partial pressure limit.
When planning a dive, determine the MOD based on the verified oxygen percentage and the applicable ppO₂ limit, then check that the planned depth stays within this limit.
MOD for Common Nitrox Mixes
The maximum operating depth (MOD) varies between Nitrox mixtures. Using 1.4 ATA as the reference oxygen partial pressure limit, DAN lists the MOD for EAN32 as approximately 34 m (112 ft) and for EAN36 as approximately 29 m (95 ft).
| Nitrox Mixture |
Oxygen Percentage |
MOD at a Reference Limit of 1.4 ATA |
| EAN32 |
32% |
Approximately 34 m / 112 ft |
| EAN36 |
36% |
Approximately 29 m / 95 ft |
This means that the same planned depth can result in different oxygen exposure limits for different gas mixtures.
For example, assume a planned depth of 30 m and use a simplified pressure conversion for seawater diving near sea level, treating the absolute ambient pressure at this depth as approximately 4 ATA. Using the oxygen partial pressure formula, the results for the two mixtures are:
- EAN32: 0.32 × 4 = 1.28 ATA < 1.4 ATA
- EAN36: 0.36 × 4 = 1.44 ATA > 1.4 ATA
Under the conditions used in this example, 30 m is within the MOD for EAN32 but exceeds the MOD for EAN36. The reason is not a change in diving depth, but the higher oxygen percentage in EAN36, which produces a higher oxygen partial pressure at the same ambient pressure.
When using an MOD table, first identify the planned depth, then use the verified oxygen percentage and applicable ppO₂ limit to confirm whether the planned depth falls within the MOD for the gas mixture being used.

How Do Dive Computers Help Monitor Nitrox Limits?
Nitrox-compatible dive computers display NDL, current oxygen partial pressure (ppO₂) and maximum operating depth (MOD), helping you track your nitrogen and oxygen limits throughout the dive.
On Suunto Nautic, for example, there are three key readings to watch during a dive:
1. NDL: Track Your Remaining No-Decompression Time
NDL changes with depth and time. It gets shorter as you go deeper, and it keeps counting down the longer you stay at depth. Use the remaining time alongside your dive plan to decide when to leave your current depth and start your ascent. Act well before your NDL reaches zero.
2. Current ppO₂: Watch How Close You Are to Your Set Limit
As you descend, rising ambient pressure pushes ppO₂ up, with the oxygen percentage unchanged. Keep an eye on the current ppO₂ reading against the limit set on your dive computer. As it approaches the limit, adjust your depth according to your dive plan and stop descending.
3. MOD: Keep Your Depth Within Your Gas's Maximum Operating Depth
MOD is the maximum operating depth for the gas you're breathing. Throughout the dive, compare your current depth with the MOD to make sure you stay within it. As you approach the MOD, stop descending and adjust your depth according to your dive plan.

What Are the Benefits and Limitations of Nitrox Diving?
The Benefits
1. Longer No-Decompression Limits
Under comparable depth and conditions, the lower nitrogen partial pressure of Nitrox generally means your tissues absorb less nitrogen, which can extend your no-decompression limit. At the same depth, for example, your calculated NDL on EAN32 may be longer than on regular air.
2. Greater Flexibility for Repetitive Diving
Nitrox can also help if you're doing several dives in a day or diving on consecutive days. Under otherwise similar conditions, lower nitrogen uptake may leave a lower residual nitrogen load after each dive, giving you more flexibility when planning the next one. Surface intervals and residual nitrogen calculations still apply in full.
Risks and Limitations
Diving with Nitrox requires an understanding of oxygen toxicity risks, gas-specific depth limits, and the fact that it does not eliminate the risk of decompression sickness.
1. Risk of Oxygen Toxicity
Excessively high oxygen partial pressure or prolonged oxygen exposure can increase the risk of oxygen toxicity. Central nervous system (CNS) oxygen toxicity is a particular concern. In severe cases, it can cause convulsions and lead to loss of consciousness underwater.
2. Maximum Operating Depth (MOD) Limitations
Different Nitrox mixtures have different maximum operating depths (MODs). Before diving, you must confirm that the planned depth does not exceed the MOD for the gas mixture being used.
3. Continued Risk of Decompression Sickness
Although Nitrox can reduce nitrogen uptake under comparable diving conditions, it still contains nitrogen and does not eliminate the risk of decompression sickness (DCS).
4.Cumulative Oxygen Exposure Limits
For repetitive dives or diving on consecutive days, you need to account for cumulative oxygen exposure across multiple dives, particularly central nervous system (CNS) oxygen exposure. A single dive also has oxygen exposure limits, so staying within the planned MOD does not automatically mean that oxygen exposure is within safe limits. Oxygen exposure also depends on oxygen partial pressure and exposure time.
5. Gas Analysis and Training Requirements
Unlike regular air diving, Nitrox diving requires you to use an oxygen analyzer to verify the actual oxygen percentage in the tank before the dive and enter the measured result correctly into your dive computer. Divers must also complete appropriate Nitrox training to understand how to confirm the maximum operating depth (MOD), manage oxygen exposure limits, and plan dives based on the gas mixture.

What Should You Check Before a Nitrox Dive?
Before diving with Nitrox, you need to verify the actual oxygen percentage in the tank and make sure the gas settings on your dive computer match the analysis results.
Checking Your Nitrox Mix
Before using Nitrox, verify the actual oxygen percentage in the tank and check that the analysis results match the tank label and the gas information in your dive plan.
DAN's breathing gas safety guidelines recommend checking the gas in each tank and analyzing its oxygen content before diving to confirm the actual oxygen percentage of the breathing gas.
Before diving with Nitrox, follow these steps to verify the actual gas composition in your tank:
1. Verify the actual oxygen percentage: Use an appropriate gas analyzer and follow the proper procedures to confirm the oxygen percentage of the actual gas mixture in the tank. Do not rely on the tank label alone to determine the gas composition.
2. Check the tank label: Make sure the gas identification on the tank matches the actual analysis results.
3. Confirm the gas information in your dive plan: Based on the measured oxygen percentage, make sure the gas mixture recorded in your dive plan matches the gas in the tank.
4. Resolve any discrepancies: If the analysis results do not match the tank label or dive plan, identify and resolve the discrepancy first. Do not use the tank for diving until its gas composition has been verified.
All subsequent dive planning should be based on the verified gas composition, not unconfirmed label information or expected values.
Checking Your Dive Computer Settings
Before using Nitrox, make sure the gas settings on your dive computer match the actual gas analysis results and your dive plan. The following items typically need to be checked:
1. Dive mode and currently selected gas: Make sure the device is in the appropriate mode for the planned dive and that the currently selected gas matches the mixture you will actually use.
2. Oxygen percentage (O₂%): Enter the oxygen percentage based on the gas analysis results for this dive, and check that the results match the information on the tank label. Do not simply rely on the device's default value or gas settings from a previous dive.
3. Oxygen partial pressure limit (ppO₂): Confirm that the ppO₂ limit set on the device is appropriate for your dive plan and the training you have received.
4. Maximum operating depth (MOD): Check the MOD calculated by the device based on the oxygen percentage and ppO₂ limit, and compare it with the planned maximum depth.
Alongside these gas-specific checks, review the predive checks for Suunto dive computers for broader device checks before entering the water.

Using Suunto Nautic as an example, gas, decompression algorithm, and alarm settings are saved separately for each dive mode. Changes made in one mode are not automatically applied to other modes. Therefore, even if you have configured Nitrox before, you still need to verify the gas settings in the dive mode you are currently using.
Step 1: Select the Dive Mode
Menu path: Dive mode selection screen
Suunto Nautic offers two scuba diving modes:
- Single gas: Designed for no-decompression recreational dives using a single gas. The gas can be either regular air or Nitrox.
- Multigas: Designed for dives that require the use of multiple gases during the dive.
If you are using only one Nitrox mixture for a no-decompression recreational dive, select Single gas mode.

Step 2: Check the Currently Selected Gas
Menu path: Surface screen → Gases
From the surface screen, open the dive settings and select the Gases menu to view the current gas list and the status of each gas.

In the gas list, check that the Nitrox mixture you plan to use is in the correct status. If the mixture you need is not listed, you can create a new gas configuration by selecting New gas, then set it to Active or Enabled depending on the dive mode.
The different gas statuses on Suunto Nautic mean the following:
- Active: The currently selected active gas. Only one gas can be set as Active in Single gas mode.
- Enabled: A gas that is enabled in Multigas mode and included in the dive plan and decompression calculations.
- Disabled: A gas that is not currently enabled and is excluded from gas switching and related calculations for the dive.
In Multigas mode, the dive computer treats all Enabled gases as gases that may be used during the planned dive and includes them in its decompression calculations. Therefore, only enable gases you are actually carrying and plan to use for the dive. Keep all other gases set to Disabled.
Step 3: Enter and Verify the Oxygen Percentage
Menu path: Gases → Select the Gas → Edit gas → Gas mixture
Open the edit screen for the corresponding gas and locate the O₂ (oxygen percentage) setting. Enter the value based on the actual oxygen percentage measured by the gas analyzer.
For example, if the gas analysis shows EAN32, set the device's O₂% to 32% rather than using the default air setting of 21%.

Suunto Nautic's Single gas mode allows the oxygen percentage to be set within a range of 21%–100%. After entering the value, check again that the number displayed on the device matches the actual analysis results.
Note: Always verify the actual gas composition before each dive and set the O₂% based on the analysis results for that dive. Also, make sure the gas analysis results match the tank label. Do not simply reuse the device's default value or settings from a previous dive.
Step 4: Check the Oxygen Partial Pressure Limit
Menu path: Gases → Select the Gas → Edit gas → Gas mixture → ppO₂
In the gas edit screen, locate the ppO₂ setting. Based on your dive plan and the training you have received, confirm that the oxygen partial pressure limit set on the device is appropriate.
Suunto Nautic offers ppO₂ settings of 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, and 1.6 bar, with a default value of 1.4 bar. The default setting is not suitable for every dive plan and should not be treated as a universal recommendation.
Note: Do not change the ppO₂ limit arbitrarily without understanding the implications. Confirm the setting based on your dive plan and applicable training requirements.
Step 5: Check the MOD and Confirm the Gas Settings
Menu path: Gases → Select the Gas → Edit gas → Gas mixture
After setting the oxygen percentage and ppO₂ limit, check the MOD displayed on the gas edit screen.
The device calculates the maximum operating depth for the gas mixture based on the entered oxygen percentage and ppO₂ limit. Compare the displayed MOD with the maximum depth in your dive plan to make sure the planned depth does not exceed the MOD for that gas mixture at the current ppO₂ limit.
Keep in mind that MOD is the maximum operating depth calculated from the current gas's oxygen percentage and ppO₂ limit, not a recommended diving depth. Your actual dive plan must also account for other limits, including NDL, dive time, and cumulative oxygen exposure.

After completing the settings above, return to the surface screen and double-check the current dive mode and enabled gas.